|
IHEP 98 - 57
| |
---|---|---|
Belikov S.V., Gurzhiev S.N., Lipaev V.V., Vasiliev I.A. | ||
Calorimeter BARS Calibration by Stopped Muons | ||
Protvino, 1998.- p.9, figs. 5, tables 2, refs.:4. | ||
The calibration method of the Big liquid argon spectrometer (BARS), which is a part of the Tagged Neutrino Facility of 70 GeV PS in Serpukhov is based on stopped muons detection. An iterative way of the calibration coefficient determination, founded on the comparison of the experimental data and the results of simulation, which were obtained with the experimental values of noises and threshoulds of data acquisition system read-out taken into account, is described. This calibration method may also be used for other highly granulated calorimeters with low detection threshoulds.
ZIPped PostScript |
Preprints'98 list | Support team |