O.K.Beliaev, Yu.A.Budanov, I.A.Zvonarev, S.V.Ivanov, E.V.Mazurov, A.P.Maltsev, V.V.Nizhegorodcev, S.A.Strekalovskih, V.A.Tepliakov, A.A.Timofeev, B.A.Frolov
Linear Accelerator as Injector for Center of Proton-Beam Therapy
Protvino, 2008. – p. 19, figs. 18, refs.: 2.


This paper describes beam dynamic simulations and design studies for a project of linear accelerator with a radiofrequency quadrupole focusing (RFQ). Proton linac for 5 MeV, the proposed injector for the Center of proton-beam therapy in the Botkin’s Hospital (Moscow), is described. This accelerator will consist of two sections. The front-end section is a conventional RFQ, the second one being an RFQ DTL structure. Sections would be assembled as H-type cavities.


ZIPped PostScript PDF